Active Thermal Testing of Delaminations in Heat-Shielding Structures
- Авторы: Chulkov A.O.1, Vavilov V.P.1,2, Moskovchenko A.I.1
-
Учреждения:
- Tomsk Polytechnic University
- Tomsk State University
- Выпуск: Том 55, № 3 (2019)
- Страницы: 240-247
- Раздел: Thermal Methods
- URL: https://journals.rcsi.science/1061-8309/article/view/182087
- DOI: https://doi.org/10.1134/S1061830919030033
- ID: 182087
Цитировать
Аннотация
We describe possibilities offered by active thermal testing when detecting delaminations of heat-shielding coatings from a metal base using an optical thermal-stimulation source that implements heating in a scanning mode. Results of numerical simulation of thermal processes are given for various defective situations. The thermophysical characteristics of heat-shielding materials have been experimentally determined, and the limits of the thermal method have been estimated for heat-shielding thickness and defect size.