Study of the touch-sensitive direct-filling dispenser
- Авторы: Batyr F.1, Salamandra B.1
-
Учреждения:
- Blagonravov Mechanical Engineering Research Institute of the Russian Academy of Sciences
- Выпуск: Том 46, № 1 (2017)
- Страницы: 70-76
- Раздел: Experimental Mechanics, Diagnostics, and Testing
- URL: https://journals.rcsi.science/1052-6188/article/view/193205
- DOI: https://doi.org/10.3103/S1052618817010022
- ID: 193205
Цитировать
Аннотация
The touch-sensitive direct-filling dispenser, in which the dose is defined by the distance between the sensor of the position of the free-floating piston located on the external side of the measuring sleeve, has been described. The factors that most significantly affect the dosing errors have been analyzed. The results of the experimental study of the dosing accuracy that depend on the pressure in the product pipeline and dispenser control algorithm have been given.