On the contamination of membrane–electrode assembles of water electrolyzers with solid polymer electrolyte by the elements of titanium alloys
- Авторы: Grigoriev S.A.1, Bessarabov D.G.2, Glukhov A.S.1,3
-
Учреждения:
- National Research University “Moscow Power Engineering Institute,”
- HySA Infrastructure Center of Competence
- National Research Center “Kurchatov Institute”
- Выпуск: Том 53, № 8 (2017)
- Страницы: 808-812
- Раздел: Article
- URL: https://journals.rcsi.science/1023-1935/article/view/188944
- DOI: https://doi.org/10.1134/S1023193517080067
- ID: 188944
Цитировать
Аннотация
The aspects of contamination of membrane–electrode assemblies of water electrolyzers with solid polymer electrolyte by the elements of titanium alloys (Ti and Fe) are considered. These alloys are used as the material for current collectors/gas-diffusion electrodes, bipolar plates, and other elements of electrolysis system. It is shown that titanium is one of the main impurities that contaminate the membrane and electrocatalytic layers of membrane–electrode assembly in the case that deionized water is used as the reagent. The membrane contamination can lead to the degradation of electrolyzer characteristics and its failure.
Об авторах
S. Grigoriev
National Research University “Moscow Power Engineering Institute,”
Автор, ответственный за переписку.
Email: sergey.grigoriev@outlook.com
Россия, Krasnokazarmennaya st. 14, Moscow, 111250
D. Bessarabov
HySA Infrastructure Center of Competence
Email: sergey.grigoriev@outlook.com
ЮАР, Potchefstroom, 2520
A. Glukhov
National Research University “Moscow Power Engineering Institute,”; National Research Center “Kurchatov Institute”
Email: sergey.grigoriev@outlook.com
Россия, Krasnokazarmennaya st. 14, Moscow, 111250; Akad. Kurchatov sq. 1, Moscow, 123182
Дополнительные файлы