Total Reflux Operating Mode of Apparatuses of a Membrane Column Type during High Purification of Gases to Remove a Highly Permeable Impurity


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Performance of a three-module membrane column in high gas purification processes to remove highly permeable impurities has been experimentally evaluated using the separation of the CH4/CO2 binary gas mixture (CO2 content of 1 vol %) as an example. The time to reach the steady-state regime in a total reflux operating mode has been determined for two configurations, the three-module membrane column (TMC) and the continuous membrane column (CMC) proposed by Hwang with colleagues. The influence of the efficiency of removal of the highly permeable impurity on the degree of purification of the low-permeability target component has been shown. The obtained product purity has appeared to be 99.997 or 99.93% at the recovery rate of 15 or 81%, respectively. It has been demonstrated that the three-module membrane column hold promise for use in high gas purification.

作者简介

A. Atlaskin

Nanotechnology and Biotechnology Department

Email: nbt@nntu.nnov.ru
俄罗斯联邦, Nizhny Novgorod, 603950

M. Trubyanov

Nanotechnology and Biotechnology Department

Email: nbt@nntu.nnov.ru
俄罗斯联邦, Nizhny Novgorod, 603950

N. Yanbikov

Nanotechnology and Biotechnology Department

Email: nbt@nntu.nnov.ru
俄罗斯联邦, Nizhny Novgorod, 603950

M. Bukovsky

Nanotechnology and Biotechnology Department

Email: nbt@nntu.nnov.ru
俄罗斯联邦, Nizhny Novgorod, 603950

P. Drozdov

Nanotechnology and Biotechnology Department

Email: nbt@nntu.nnov.ru
俄罗斯联邦, Nizhny Novgorod, 603950

V. Vorotyntsev

Nanotechnology and Biotechnology Department

Email: nbt@nntu.nnov.ru
俄罗斯联邦, Nizhny Novgorod, 603950

I. Vorotyntsev

Nanotechnology and Biotechnology Department

编辑信件的主要联系方式.
Email: nbt@nntu.nnov.ru
俄罗斯联邦, Nizhny Novgorod, 603950

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2018