Resonators for In Vivo Imaging: Practical Experience


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

Resonators for preclinical electron paramagnetic resonance imaging have been designed primarily for rodents and rabbits and have internal diameters between 16 and 51 mm. Lumped-circuit resonators include loop-gap, Alderman–Grant, and saddle coil topologies and surface coils. Bimodal resonators are useful for isolating the detected signal from incident power and reducing dead time in pulse experiments. Resonators for continuous wave, rapid scan, and pulse experiments are described. Experience at the University of Chicago and University of Denver in design of resonators for in vivo imaging is summarized.

作者简介

George Rinard

Center for EPR Imaging In Vivo Physiology, Department of Chemistry and Biochemistry and School of Engineering and Computer Science, University of Denver

Email: geaton@du.edu
美国, 2101 E. Wesley Ave, Denver, CO, 80210

Richard Quine

Center for EPR Imaging In Vivo Physiology, Department of Chemistry and Biochemistry and School of Engineering and Computer Science, University of Denver

Email: geaton@du.edu
美国, 2101 E. Wesley Ave, Denver, CO, 80210

Laura Buchanan

Center for EPR Imaging In Vivo Physiology, Department of Chemistry and Biochemistry and School of Engineering and Computer Science, University of Denver

Email: geaton@du.edu
美国, 2101 E. Wesley Ave, Denver, CO, 80210

Sandra Eaton

Center for EPR Imaging In Vivo Physiology, Department of Chemistry and Biochemistry and School of Engineering and Computer Science, University of Denver

Email: geaton@du.edu
美国, 2101 E. Wesley Ave, Denver, CO, 80210

Gareth Eaton

Center for EPR Imaging In Vivo Physiology, Department of Chemistry and Biochemistry and School of Engineering and Computer Science, University of Denver

编辑信件的主要联系方式.
Email: geaton@du.edu
ORCID iD: 0000-0001-7429-8469
美国, 2101 E. Wesley Ave, Denver, CO, 80210

Boris Epel

Center for EPR Imaging In Vivo Physiology, Department of Radiation and Cellular Oncology, University of Chicago

Email: geaton@du.edu
美国, Chicago, IL

Subramanian Sundramoorthy

Center for EPR Imaging In Vivo Physiology, Department of Radiation and Cellular Oncology, University of Chicago

Email: geaton@du.edu
美国, Chicago, IL

Howard Halpern

Center for EPR Imaging In Vivo Physiology, Department of Radiation and Cellular Oncology, University of Chicago

Email: geaton@du.edu
美国, Chicago, IL

补充文件

附件文件
动作
1. JATS XML

版权所有 © Springer-Verlag GmbH Austria, 2017