Biological osteosynthesis in fractures of the trochanteric region of the femur

封面

如何引用文章

全文:

详细

New interlocking metal-polymeric fixative of the seventh generation for closed osteosynthesis in trochanteric fractures is elaborated and introduced into practice. The strength of the «bonefixative» system is calculated. The suggested fixative and the technique of its use meet the criteria of biologic (low invasive) osteosynthesis, provides the possibility to perform surgery via small skin incisions and thus minimizes the risk of intra- and post-operative complications.

作者简介

I. Rublenik

Bukovina State Medical Academy

Email: info@eco-vector.com
乌克兰, Chernivtsi

V. Vasyuk

Bukovina State Medical Academy

Email: info@eco-vector.com
乌克兰, Chernivtsi

A. Shayko-Shaykovskiy

Chernivtsi National University

编辑信件的主要联系方式.
Email: info@eco-vector.com
乌克兰, Chernivtsi

参考

  1. Рубленик І.М., Васюк В.Л., Шайко-Шайковсъкий О.Г. //Буковинський мед. вісн. — 1999.— Т.3, N 1. — С. 100-106.
  2. Albareda J., Laderiga A., Palanca D. et al. //Int. Orthop. - 1996. — Vol. 20. — P. 47-50.
  3. Borgquist L., L.indelow G., Tborngren K-G. //Acta Orthop. Scand. — 1991. — Vol. 62. — P. 39-48.
  4. Ceder L., Lunsjo K., Ollson O. et al. //Orthop. Trans. — 1996.— Vol. 20.— P. 162-163.
  5. Cooper C., Campion G., Melton L. J. //Osteoporosis Int. - 1992. — Vol. 2. — P. 285-289.
  6. Gundle R., Garqan M.F., Simpson A. //Injury. — 1995. — Vol. 26. — P. 611-614.
  7. Kannus P., Parkkari J., Sievanen H. et al. //Bone. — 1996. — Vol. 18. — P. 576-635.
  8. Keene G.S., Parker M.J., Pryor G.A. //Brit. Med. J. — 1993. — Vol. 307. — P. 1248-1250.
  9. Kykla C., Heins T., Berger G. et al. //Acta Chir. Austriaca. - 1997. — Bd 5. — S. 290-293.
  10. Medoff R.J., Maes K. //J. Bone Jt Surg. — 1991. — Vol. 73A. — P. 1192-1199.
  11. Schumpelick W., Jantzen P.M. //J. Bone Jt Surg. — 1955. — Vol. 37A. — P. 693-698.
  12. Seibert F.G., Schippinger G., Szyszkowitz R. //Acta Chir. Austriaca. — 1997. — Bd 5. — S. 294-295.
  13. Thornton L. //Piedmont Hosp. Bull. — 1937. — Vol. 10.— P. 21-27.
  14. Treharne R.W. //Orthop. Rev. — 1982. — Vol. 11. — P. 45-52.
  15. Zuckerman J.D. //New Engl. J. Med. — 1996. — Vol. 334. — P. 1519-1525.

补充文件

附件文件
动作
1. JATS XML
2. Fig. 1. Locking metal-polymer retainer of the seventh model and the scheme of its application.

下载 (359KB)
3. Fig. 2. Radiographs of patient N. on admission (a) and 3.5 months after surgery (b).

下载 (601KB)

版权所有 © Eco-Vector, 2003



##common.cookie##