Improving the Electrical Characteristics of Measuring Devices Based on Rail-to-Rail Operational Amplifiers
- Авторы: Sergeev A.1, Suvorov A.1
-
Учреждения:
- Ural Federal University
- Выпуск: Том 61, № 8 (2018)
- Страницы: 817-823
- Раздел: Article
- URL: https://journals.rcsi.science/0543-1972/article/view/246570
- DOI: https://doi.org/10.1007/s11018-018-1508-0
- ID: 246570
Цитировать
Аннотация
A method by means of which the dynamic range of signals may be increased and the dynamic error of the input stages of measuring devices based on Rail-to-Rail operational amplifiers reduced is described. The electrical circuit of the equipment is developed. Results of testing of Rail-to-Rail operational amplifiers in tracking power supply are presented.
Об авторах
A. Sergeev
Ural Federal University
Email: izmt@vniims.ru
Россия, Ekaterinburg
A. Suvorov
Email: izmt@vniims.ru