Measurement of the Flow Rate of Liquid Metal Coolants in Fast Neutron Reactors
- Авторы: Welt I.1, Mikhailova Y.1, Sudarikov V.1
-
Учреждения:
- Research Institute Teplopribor
- Выпуск: Том 61, № 1 (2018)
- Страницы: 28-36
- Раздел: Mechanical Measurements
- URL: https://journals.rcsi.science/0543-1972/article/view/246377
- DOI: https://doi.org/10.1007/s11018-018-1383-8
- ID: 246377
Цитировать
Аннотация
We investigate the influence of the magnetic Reynolds number Rem on the signal from electrodes in an the electromagnetic flowmeter. Conditions for eliminating this dependence by applying an inhomogeneous magnetic field, several pairs of electrodes, and a numerical integration algorithm are considered. We demonstrate the possibility of calibrating the flowmeter using a low-capacity liquid-metal flow fixture.
Ключевые слова
Об авторах
I. Welt
Research Institute Teplopribor
Email: vksudarikov@mail.ru
Россия, Moscow
Yu. Mikhailova
Research Institute Teplopribor
Email: vksudarikov@mail.ru
Россия, Moscow
V. Sudarikov
Research Institute Teplopribor
Автор, ответственный за переписку.
Email: vksudarikov@mail.ru
Россия, Moscow