Measurement of DC and AC Response Curves of a Bipolar Transistor as a Function of Frequency


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

We discuss improving the reliability of measured DC and AC response curves for a bipolar transistor as a function of frequency using the mass-produced 2T937 transistor (Russia) as an example. We describe preparations for measurement and the actual measurements in considerable detail. We provide experimental response curves for the 2T937 transistor. A special test (measurement) board was developed to prevent the measured response curves from being affected in any way by the transistor mount or interface hardware (power buses, soldering leads, matching devices, adapters, etc.). A bare transistor chip was used to eliminate any effect of the transistor package on the results and improve the size and weight specifications of devices using the 2T937 transistor. The transistor chip can be directly mounted to a test board whose topology is used to connect the transistor chip to the device. The microstripline board is designed to enable measurements to be performed in the microwave frequency band using a probe station with standard calibration.

作者简介

A. Titkov

NPP Almaz

编辑信件的主要联系方式.
Email: titkov-1973@yandex.ru
俄罗斯联邦, Saratov

A. Khvalin

Saratov State University

Email: titkov-1973@yandex.ru
俄罗斯联邦, Saratov

补充文件

附件文件
动作
1. JATS XML

版权所有 © Springer Science+Business Media, LLC, part of Springer Nature, 2019