Method for reaching air-tightness of the joint between the casing of an impeller pump and its cover


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

A method is considered to reach the air-tightness of the flange joint of the casing of an impeller pump with its cover using an anaerobic sealant instead of a gasket made of a thermoplastic material. The possible causes of leakage of working fluids that are related to the errors of machining flange surfaces and the specific features of their assembly are shown. The properties of anaerobic sealants that ensure the air-tightness of the flange joints are presented.

作者简介

O. Ryakhovskii

Bauman Moscow State Technical University

Email: malyin@mail.ru
俄罗斯联邦, ul. Vtoraya Baumanskaya 5, Moscow, 105005

G. Malysheva

Bauman Moscow State Technical University

编辑信件的主要联系方式.
Email: malyin@mail.ru
俄罗斯联邦, ul. Vtoraya Baumanskaya 5, Moscow, 105005

A. Vorob’ev

Bauman Moscow State Technical University

Email: malyin@mail.ru
俄罗斯联邦, ul. Vtoraya Baumanskaya 5, Moscow, 105005


版权所有 © Pleiades Publishing, Ltd., 2016