Electrical Conditions of Foundry Operation of DC and AC Arc Furnaces


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

The electrical conditions of operation of ac and dc 0.5- to 25-t furnaces, namely, the installed, active and net powers, the maximum electric arc voltage, the electric arc operating current, and the electrical efficiency, are considered and compared. The parameters of a dc twin furnace, where one power supply is used for two furnaces and the periods of melting and finishing of a liquid metal in these furnaces are separated in time, are analyzed.

Sobre autores

M. Krutyanskii

OO NPF COMTERM

Autor responsável pela correspondência
Email: comterm@comterm.ru
Rússia, Moscow

S. Nekhamin

OO NPF COMTERM

Email: comterm@comterm.ru
Rússia, Moscow

M. Mitrofanov

OO NPF COMTERM

Email: comterm@comterm.ru
Rússia, Moscow


Declaração de direitos autorais © Pleiades Publishing, Ltd., 2018

Este site utiliza cookies