Characteristics of electric arc furnaces powered by a low-frequency alternating current
- Authors: Mironov Y.M.1, Mironova A.N.1
-
Affiliations:
- Chuvash State University
- Issue: Vol 2016, No 6 (2016)
- Pages: 485-489
- Section: Simulation of Metallurgical and Thermal Processes
- URL: https://journals.rcsi.science/0036-0295/article/view/170594
- DOI: https://doi.org/10.1134/S0036029516060112
- ID: 170594
Cite item
Abstract
The changes in the parameters of a DSP-100 electric arc furnace that are induced by a decrease in the current frequency are considered. It is shown that the related decrease in the current lead resistances causes an increase in the arc power and voltage, a decrease in the reactive power, and an increase in the electrical efficiency and the power coefficient. The heat indices are expected to be significantly improved.